# KB6011盖革计数器 **Repository Path**: kongba777/KB6011 ## Basic Information - **Project Name**: KB6011盖革计数器 - **Description**: KB6011系列盖革计数器,核辐射检测仪。 - **Primary Language**: C - **License**: GPL-3.0 - **Default Branch**: master - **Homepage**: None - **GVP Project**: No ## Statistics - **Stars**: 0 - **Forks**: 0 - **Created**: 2019-06-12 - **Last Updated**: 2026-02-17 ## Categories & Tags **Categories**: Uncategorized **Tags**: None ## README If need to purchase the KB6011 Geiger counter, you can place an order on eBay or AliExpress. # User Manual for KB6011 Fourth-Generation Nuclear Radiation Detector, 2024 Edition ## Personal Dosimeter, Revised in 2024 ### Function Overview: - **Geiger counter click sound** (continuous clicking) - **CPS/CPM statistics and maximum value function** - **Threshold alarm signal statistics** - **Turbo Q3.5** - **Special alloy compensation coating** - **Type-C firmware updates** - **Adjustable advanced parameters** ![391f9ae88ac3d1f4](https://github.com/user-attachments/assets/ff452383-d606-4e9e-aa6c-333a2fe4adde) ### Detection Methods: - **General Testing Methods:** Place the device against the testing object, wait for 60 seconds (4 cycles), and ensure the readings stabilize. For marble radiation testing, the recommended testing time is 5 minutes; check the average values afterward. - **Iodine-131 Test:** Place the device near the patient’s affected area. Wait about 1 minute and check the real-time value. - **Ambient Radiation Test:** Place the device 1 meter above the ground, avoiding beta radiation from the ground. Conduct testing in open spaces for 5 minutes and observe the average readings on the display. - **Radiation Source Search:** Switch the display to the histogram interface and scan the object near the back of the device. Observe the graphical display and listen for alarm sounds. - **DR/X-ray Leakage Test:** Observe the device's instant readings when exposed to radiation. ![O1CN0198Uyig1uX7SFADeGy_!!87456046](https://github.com/user-attachments/assets/13eacb81-7469-4a6d-a871-e7ad4134d87d) ### Product Use: - **Personal Use:** For daily home protection and workplace personal safety. Radiation detection during home renovations, travel protection, ore detection, jade, negative ions in soil, marble, ceramic tiles, and mineral samples. - **Hobbyist Use:** Suitable for antique enthusiasts, metal detectors, negative ion powders, decorative materials, and ceramic tile detection. - **Professional Use:** Detect radiation leakage from X-ray machines, CT, DR, CBCT, and other equipment. Detect industrial and medical radiation sources. Includes detection for patients who have been injected or treated with certain radiation-emitting medical substances (e.g., PET, bone scans). Suitable for medical professionals for personal protection. ### Product Parameters: - **Radiation types detected:** γ, X-rays (> 48KeV), solid β - **Range:** 5000 μSv/h - **Accuracy:** Error < +25+2/H(10) % (positive error) - **Sensitivity:** 130 CPM/μSv/h - **Resolution:** 0.01 μSv/h - **Testing speed:** 1 second (at 10 μSv/h) - **Background refresh time:** 15 seconds - **Size:** 117 x 49 x 19.5 mm - **Lithium battery:** 1200mAh, 3.7V - **Battery runtime:** 60 hours - **Weight:** 110g (flight approved) ### Package Contents: - Device — 1 piece - Type-C cable — 1 piece - User manual — 1 sheet ![1](https://github.com/user-attachments/assets/26234838-d918-4eba-8481-c71377fe85a5) ### National Standard Radiation Thresholds: - **>0.5 μSv/h:** Exceeds average level, note the scenario #### Radiation Levels: - **Natural ambient radiation level:** 0.1~0.20 μSv/h (normal background level) - **Indoor radiation level:** 0.25 μSv/h (closed room radiation level) - **Marble and ceramic tile radiation level:** 0.30~0.40 μSv/h (possible levels from construction materials) - **National standard radiation alarm level:** 0.50 μSv/h (alarm level; protective measures may be required above this level) - **Airplane radiation level:** 2-3 μSv/h (radiation level during flights, reducing flight frequency recommended) - **Vintage camera lens radiation level:** <20 μSv/h (vintage lenses may contain trace radiation-emitting materials; handle with care) - **Small ore radiation level:** 40+ μSv/h (ore, avoid contact) - **Energy stone radiation level:** 100 μSv/h (some energy stones, maintain distance) - **Medical treatment radiation level:** 100+ μSv/h (follow medical advice for specific procedures) - **X-ray machine internal radiation level:** 2000+ μSv/h (instantaneous value, restricted area) - **CT scan radiation level:** 9999+ μSv/h (several dozen mSv; follow medical advice, only when necessary) ### Warranty: 18-month official warranty. ### Additional Features: - Users can install and replace preferred Geiger-Müller counters, including J321, J305, M4011, SBM20, RD003, and others. - Press and hold both the up and down buttons simultaneously to enter the advanced settings page, where you can configure the calibration coefficient (Cf), sensor probe model, Geiger counter voltage, and more. ### Simplified Ul Operation Guide: --- ![kb6011-简明图解英文版](https://github.com/user-attachments/assets/38c635fa-e952-4ce4-ae4d-80b3b48f1daa) The **Geiger Counter KB6011** is equipped with advanced features for radiation detection and analysis. Designed for ease of use and comprehensive functionality, this device includes self-test capabilities, flexible voltage settings, statistical functions, and real-time monitoring options. Below is a detailed list of its features: --- ### Optimized List of Functions: 1. **Self-Test Page** - A 10-minute self-test ensures the device is operating correctly. - Displays firmware version and PCB (Printed Circuit Board) model. - Accessible by: - Starting the device for the first time. - Pressing the "ClearData" button 30 times continuously and restarting. 2. **Real-Time CPM Function (Counts Per Minute)** - Real-time display of radiation particles per minute for accurate monitoring. - Includes a 3-minute moving average for better trend analysis. - Features a 15-second timer for quick measurements. 3. **Statistical Functions** - **Contact**: Counts the number of radiation exposure events (alarm triggers). - **Exp.Time**: Tracks the total duration of radiation exposure. 4. **Inst.val Instant Retention** - Retains peak radiation moments with a 1-second statistical interval. - Bar chart visualization makes data analysis easier. 5. **Particle Sound On/Off** - Customizable sound settings: - **C.O.L Mode**: Disable alarm sound while retaining particle detection sound. - **A.O.I Mode**: Disable particle detection sound while retaining alarm sound. - Buzzer alarm activates when radiation levels exceed >1 µSv/h. 6. **Hidden Settings Access** - Access advanced configuration options by pressing and holding the ↑ and ↓ buttons simultaneously. 7. **500V Voltage Support** - Supports multiple tube voltage levels: 350V, 400V, 450V, and 500V. - Adjustable voltage to prevent brush discharge or to increase sensitivity by up to 10%. - Default voltage is 450V, configurable to meet specific conditions. 8. **Upcoming Tube Compatibility** - Planned future support for **LND7317 tubes**, along with other additional tube models. --- # How to Burn Firmware in the Future? We use GD32 chips, so first download the corresponding burning software. - **Burning software**: GigaDevice_MCU_ISP_Programmer_V3.0.2.5782 - **Firmware**: HEX file V4.3.0.hex - **Serial port driver**: CH340E serial port chip driver ## Preparations for Updating: 1. Connect the device to a Windows system computer via USB first. 2. Launch the GigaDevice_MCU_ISP_Programmer. 3. First, press and hold the "upper" button without releasing it. After a few milliseconds, use another finger to simultaneously press and hold the "middle" button. Make sure the "upper" button is pressed before the "middle" button. Keep both buttons pressed simultaneously. This will allow the device to enter the Bootloader burning mode, and a black square will appear on the screen. This indicates that the device has entered burning mode. If the black square does not appear on the screen, repeat the process. 4. In the software, select the corresponding serial port number. The number of the serial port corresponding to CH340E. After that, proceed to the next step and go to the firmware selection page. 5. If the flash page is locked, first click to unlock it, then return to the initial screen. After that, repeat the burning steps. ## Important Notes: - During the entire burning process, do not release the power button (especially when the progress bar is scrolling) until the burning is complete. This is necessary to prevent unexpected power loss, which may lead to errors and damage to the device.