README
MIT

Modbus TCP/IP Stream

Build Status

This is a very simple module that uses NodeJS Streams2 to read Modbus TCP data and convert it to JSON and vice-versa.

Upgrade

If you're just starting or just trying to use this library, I advise you to try modbus-stream. It's more complete (it supports all standard function codes) and it was designed to work with TCP, RTU and ASCII modes.

Install

npm install modbus-tcp

Example

var modbus = require("modbus-tcp");
var client = new modbus.Client();
var server = new modbus.Server();

// link client and server streams together
client.writer().pipe(server.reader());
server.writer().pipe(client.reader());
// if you have a socket (stream) you can just
// call client.pipe(socket) or server.pipe(socket)

server.on("read-coils", function (from, to, reply) {
    return reply(null, [ 1, 0, 1, 1 ]);
});

// read coils from unit id = 0, from address 10 to 13
client.readCoils(0, 10, 13, function (err, coils) {
    // coils = [ 1, 0, 1, 1 ]
});

Client Methods

All of the following read methods have the form method(unitId, from, to, next) and write methods have the form method(unitId, addr, val, next), where next is an optional function called if the server replies (with the same transactionId) to the sent message.

  • readCoils
  • readDiscreteInputs
  • readHoldingRegisters
  • readInputRegisters
  • writeSingleCoil
  • writeSingleRegister
  • writeMultipleCoils
  • writeMultipleRegisters

Addresses are exactly as is in protocol, so if you see a paper talking about address 40001 this usually means first record address of that function so it means address 0.

Server Events

  • read-coils
  • read-discrete-inputs
  • read-holding-registers
  • read-input-registers
  • write-single-coil
  • write-single-register
  • write-multiple-coils
  • write-multiple-registers
  • data

This last event is triggered when an unknown function code is received.

Copyright 2016 Diogo Resende Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.