# Watson **Repository Path**: sympny/Watson ## Basic Information - **Project Name**: Watson - **Description**: PCB layout and test results for a simple high dynamic range power meter based on the Analog Devices AD8307 Logarithmic Amplifier. - **Primary Language**: Unknown - **License**: Not specified - **Default Branch**: master - **Homepage**: None - **GVP Project**: No ## Statistics - **Stars**: 1 - **Forks**: 0 - **Created**: 2021-09-26 - **Last Updated**: 2022-12-16 ## Categories & Tags **Categories**: Uncategorized **Tags**: None ## README Watson ====== Watson is a relatively simple RF power meter based on the "120 dB Measurement System" outlined in the Analog Devices (AD) AD8307 data sheet. Watson has a narrow and fixed measurement band centered on 10.7 MHz and was developed as the detector for a low cost spectrum analyzer design. ![Un-Populated Watson PCB](./gfx/unpopulated_pcb_800.jpg) ![Populated Watson PCB](./gfx/populated_pcb_800.jpg) ![Screen grab of Watson's Schematic](./gfx/schem_screen.jpg) ![Snapshot of Watson's Board Layout](./gfx/pcbnew_screen.jpg) ![Log Response at 10.7 MHz](./gfx/log_response_center_800.png) ![Log Frequency Response](./gfx/logfreq_response_800.png) ![Log Conformance at 10.7 MHz](./gfx/log_conformance_center_800.png)